Backup power
Inverter sizing
Estimate continuous and peak inverter power requirements from simultaneous loads and a sizing margin.
Your estimate
Updates as you type- Continuous power requirement
- 1,000 W
- Peak power requirement
- 1,800 W
An estimate based on your inputs. Example values are not current tariffs or equipment recommendations.
Check both continuous and surge ratings, surge duration, battery current and equipment compatibility before selecting an inverter.
How it works
The sizing margin is applied to continuous combined load. The required peak rating is the greater of this continuous requirement and your total simultaneous start-up peak.
Worked example
For an 800 W continuous load, a 25% margin gives 1,000 W continuous capacity. If the total simultaneous peak is 1,800 W, the peak requirement remains 1,800 W.
What to keep in mind
- Enter total simultaneous peak, including other running devices; do not add the same load twice.
- Surge duration, battery current, wiring and equipment compatibility need separate verification.
Reference sources
References explain the underlying concepts. The tool uses the simplified method stated above.